Best Quality ACSR Bare Conductor for Sale

 Best Quality ACSR Bare Conductor for Sale

Produktdetails

Basis Info

Modell Nr.:LJ/LGJ
Art: Blank
Leitertyp: Stranded
Anwendung: Oben
Leitermaterial: Aluminium
Material Form: Runddraht
Bescheinigung: ISO9001 , CE

Zusätzliche Informationen.

Warenzeichen:Jiapu
Verpackung:Wooden Drum or Wooden&Steel Drum
Standard:Bare Conductor
Herkunft:Henan, China
HS-Code:4101962331
Produktionskapazität:5000kilometer/Month

Produktbeschreibung

ACSR (Aluminum Conductor Steel Reinforced)

Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.

1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor steel reinforced (ACSR)(4) anti-corrosion type ACSR(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)

2. Relative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191

AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Packing:
Standard export wooden drums

Standards IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110
Certificate ISO 9001 and ISO 14001. CE ,SONCAP
Type AAC, AAAC, ACSR, AACSR&ACAR conductor
AAC AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
AAAC (AAAC) Conductor as per ASTM-B-399-1992
ACSR ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Standard:
ASTM B230,B231,B400 Standard

Code word Size of
Conductor
Stranding and Wire Diameter Overall Diameter Max.D.C. Resistance at 20°C Code word Size of Conductor Stranding and Wire Diameter Overall Diameter Max.D.C. Resistance at 20°C
AWG or MCM mm mm ohm/km AWG or MCM mm mm ohm/km
Peachbell 6 7/1.554 4.67 2.1692 Verbena 700 37/3.493 24.45 0.0813
Rose 4 7/1.961 5.89 1.3624 Nasturtium 715.5 61/2.75 24.76 0.0795
Lris 2 7/2.474 7.42 0.8577 Violet 715.5 37/3.533 24.74 0.0795
Pansey 1 7/2.776 8.33 0.6801 Cattail 750 61/2.817 25.35 0.0759
Poppy 1/0 7/3.119 9.36 0.5390 Petunia 750 37/3.617 25.32 0.0759
Aster 2/0 7/3.503 10.51 0.4276 Lilac 795 61/2.90 26.11 0.0715
Phlox 3/0 7/3.932 11.80 0.3390 Arbutus 795 37/3.724 26.06 0.0715
Oxlip 4/0 7/4.417 13.26 0.2688 Snapdragon 900 61/3.086 27.78 0.0632
Valerian 250 19/2.913 14.57 0.2275 Cockscomb 900 37/3.962 27.73 0.0632
Sneezewort 250 7/4.80 14.4 0.2275 Goldenrod 954 61/3.177 28.6 0.0596
Laurel 266.8 19/3.01 15.05 0.2133 Magnolia 954 37/4.079 28.55 0.0596
Daisy 266.8 7/4.96 14.9 0.2133 Camellia 1000 61/3.251 29.36 0.0569
Peony 300 19/3.193 15.97 0.1896 Hawkweed 1000 37/4.176 29.23 0.0569
Tulip 336.4 19/3.381 16.91 0.1691 Larkspur 1033.5 61/3.307 29.76 0.0550
Daffodil 350 19/3.447 17.24 0.1625 Bluebell 1033.5 37/4.244 29.72 0.0550
Canna 397.5 19/3.673 18.36 0.1431 Marigold 1113 61/3.432 30.89 0.0511
Goldentuft 450 19/3.909 19.55 0.1264 Hawthorn 1192.5 61/3.551 31.05 0.0477
Syringa 477 37/2.882 20.19 0.1193 Narcissus 1272 61/3.668 33.02 0.0477
Cosmos 477 19/4.023 20.12 0.1193 Columbine 1351.5 61/3.78 34.01 0.0421
Hyacinth 500 37/2.951 20.65 0.1138 Carnation 1431 61/3.89 35.03 0.0398
Zinnia 500 19/4.12 20.6 0.1138 Gladiolus 1510.5 61/4.00 35.09 0.0376
Dahlia 556.5 19/4.346 21.73 0.1022 Coreopsis 1590 61/4.099 36.51 0.03568
Mistletoe 556.5 37/3.114 21.79 0.1022 Jessamine 1750 61/4.302 38.72 0.0325
Meadowsweet 600 37/3.233 22.63 0.0948 Cowslip 2000 91/3.76 41.40 0.02866
Orchid 636 37/3.33 23.31 0.0894 Lupine 2500 91/4.21 46.30 0.0230
Heuchera 650 37/3.366 23.56 0.0875 Trillium 3000 127/3.90 50.75 0.0192
Flag 700 61/2.72 24.48 0.0813 Bluebonnet 3500 127/4.21 54.80 0.01653

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.

Ähnlich oder verwandt

  • No related articles