Qualitäts-Seilzug

 Qualitäts-Seilzug

Produktdetails

Basis Info

Modell Nr.:Control Cable
Anwendung: Industriell , Kraftwerk , Telekommunikation , Computer
Spannung: Nieder-und Mittelspannung Kabel
Strom: DC-Kabel
Bescheinigung: ISO , CE

Zusätzliche Informationen.

Warenzeichen:Jiapu
Verpackung:Wooden Drum or Wooden&Steel Drum
Standard:IEC, ASTM, DIN, BS, GB, Any standard
Herkunft:Henan China
HS-Code:4101962331
Produktionskapazität:5000km/Month

Produktbeschreibung

High Quality Control Cable

Control Cable 450/750V~0.6/1kV Cable, Flame-retardant copper conductor PVC insulated and sheath steel tape armoured

1. Standard

The control cable can be produced according to the standard GB9330-1988, IEC60227(60502, 60332), DIN, BS, and our factory can also manufacture the cables in accordance with other standards.

2. Scope of Application

Flame-retardant control cable is suitable for connecting wires between electric equipments with a special flame-retardant requirement in controlling, monitoring loop and protecting circuit at rated voltage up to 600/1000V(A. C. ). Our flame-retardant control cable includes A class flame-retardant control cable, special flame-retardant control cable, low smoke halogen free flame-retardant control cable, low smoke low halogen flame-retardant control cable, XLPE insulated control cable and XLPE insulated flame-retardant control cable.

3. Service Conditions

(1) The long-time working temperature of conductor of PVC insulated cable is 70oC

The long-time working temperature of conductor of XLPE insulated cable is 90oC

(2) The temperature for laying the cables can not be lower than 0oC. Permissible bending radius(r): Unarmoured cable: R≥ 6D; (D: Outer diameter of the cable); Armoured or copper-tape screened cable: R≥ 12D; Shielded flexible cable: R≥ 6D

Name Section Area(mm2) No.of Core Application Site
Copper Conductor,PVC Insulated and Sheathed Control Cable 0.75\1.0\1.5\2.5 1-16 Permanent installation indoors, in cable ditches or pipes
4\6 2-14
10 2-10
Copper Conductor,PVC Insulated and Sheathed ,Braiding Shielded Control Cable 0.75\1.0\1.5\2.5 2-61 Permanent installation indoors, in cable ditches or pipes where shielding is required
4\6 2-14
10 2-10
Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable 0.75\1.0\1.5\2.5 4-10 Permanent installation indoors, in cable ditches or pipes where shielding is required
4\6 7-61
10 4-10
Copper Conductor,PVC Insulated and Sheathed,Steel tape Armoured Control Cable 0.75\1.0\1.5\2.5 7-16 Permanent installation indoors, in cable ditches, Be able to withstand stronger external mechanical force
4\6 4-14
10 4-14
Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable 0.5-2.5 4-61 Installation indoors where flexibility and movability are required
Copper Conductor,PVC Insulated and Sheathed ,Braiding Shielded Flexible Control Cable 0.5\0.75\1.0 4-61 Installation indoors where flexibility shielding and movability are required
1.5\2.5 4-48
Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable 0.75\1.0\1.5\2.5 2-16 Permanent installation indoors, in cable ditches or pipes
4\6 2-14
10 2-10
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable 0.75\1.0\1.5\2.5 2-61 Permanent installation indoors, in cable ditches or pipes where shielding is required
4\6 2-14
10 2-10
Copper Conductor,XLPE  Insulated,Stee-tape Armoured,PVC Sheathed Control Cable 0.75\1.0\1.5\2.5 7-61 Permanent installation indoors, in cable ditches,pipes or underground.Be able to withstand stronger external mechanical force
4\6 4-14
10 4-10
Copper Conductor,XLPE  Insulated,Copper tape Screened,PVC Sheathed Control Cable 0.75\1.0\1.5\2.5 7-61 Permanent installation indoors, in cable ditches or pipes where shielding is required
4\6 4-14
10 4-10
Copper Conductor,XLPE Insulated,PVC  Sheathed Flexible Control Cable 0.5-2.5 4-61 Installation indoors where flexibility and movability are required
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable 0.5\0.75\1.0 4-61 Installation indoors where flexibility shielding and movability are required
1.5\2.5 4-48
 

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.