AAC-Überkopfleiter Aus Aluminium Für Kraftübertragung BS215


                                 AAC-Überkopfleiter Aus Aluminium Für Kraftübertragung BS215

Basis Info

Modell Nr..
AAC

Art
Blank

Leitertyp
Stranded

Anwendung
Oben

Leitermaterial
Aluminium

Isoliermaterial
Blank

Material Form
Runddraht

Bescheinigung
ISO9001 ,
CE ,
UL ,
CCC ,
RoHS

Zusätzliche Informationen.

Warenzeichen
Huatong

Verpackung
Wooden Drum

Standard
7/19/37/61/91

Herkunft
China

HS-Code
761490

Produktionskapazität
5000 Ton Per Month

Produktbeschreibung

Overhead aluminium AAC Bare conductor for power transmission BS215
(1)Production capacity:2000 ton/month
(2)MOQ:1km
(3)Delivery:5~15 officail days.
(4)Standards:IEC,ASTM,DIN,BS; or according to customers’ requirements.
(5)Delivery length:as per customers’ request.

1.Description
AAC Conductor, All Aluminium Conductor
AAC conductor is widely used in power transmission lines with various voltage levels.

2. Construction:
Aluminum alloy 1350-H-19 wires. Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

3. Refered Standards
(1). IEC 61089: Round wire concentric lay overhead electrical stranded conductors
(2). DIN 48 201-5: All Aluminium Conductors
(3). BS 215-1: Aluminium strander conductors
(4). ASTM B231: Stranded Specification for Concentric-Lay-Stranded Aluminium 1350 Conductors
(5). AS 1531: Conductors-Bare overhead-Aluminium and aluminium alloy

4.Huatong Cable Inc. 
(1) ,More than 30 years experience.
(2) ,100,000m² factory,200 staffs,annual output 100,000 metic tons.
 (3) ,Sound Quality Control
     – Material inspection;
     – manufacturing inspection;
     – Finished products inspection;
     – Inspection before delivery.
     – Third party inspection.
     – Inspection of storage at port of departure.
(4),ISO Certificated.
(5),Plenty of material and lobor gurantee the delivery prompt and price competitive.
(6),24/7 service.

5.Bare Conductor Types
(1) all aluminum conductor (AAC)
(2) all aluminum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminum conductor aluminum clad steel reinforced(ACSR/AW)
(6) rear earth aluminum conductor steel reinforced(ACSR/RE)
(7) aluminum conductor aluminum alloy reinforced(ACAR)

6.BS215 Part1 Standard

Code name Nominal
aluminum
area
Stranding
and wire
diameter
Sectional
area
Overall
diameter
Linear
mass
Max. DC
resistance
at 20 ºC
Rated strength Final
modulus
of elasticity
Coefficient
of linear
expansion
mm 2 mm mm 2 mm kg/km Ω/km daN hbar /ºC
Midge 22 7/2.06 23.33 6.18 63.8 1.227 399 5900 23.0×10 -6
Aphis 25 3/3.35 26.40 7.2 73 1.081 411 5900 23.0×10 -6
Gnat 25 7/2.21 26.8 6.6 73 1.066 459 5900 23.0×10 -6
Weevil 30 3/3.66 31.6 7.9 86 0.9082 486 5900 23.0×10 -6
Mosquito 35 7/2.59 37.0 7.8 101 0.7762 603 5900 23.0×10 -6
Ladybird 40 7/2.79 42.8 8.4 117 0.6689 687 5900 23.0×10 -6
Ant 50 7/3.10 52.83 9.30 145 0.5419 828 5900 23.0×10 -6
Fly 60 7/3.40 63.55 10.20 174 0.4505 990 5900 23.0×10 -6
Bluebottle 70 7/3.66 73.7 11.0 202 0.3881 1134 5900 23.0×10 -6
Earwig 75 7/3.78 78.5 11.4 215 0.3644 1194 5900 23.0×10 -6
Grasshopper 80 7/3.91 84.1 11.7 230 0.3406 1278 5900 23.0×10 -6
Clegg 90 7/4.17 95.6 12.5 262 0.2994 1453 5900 23.0×10 -6
Wasp 100 7/4.39 106.0 13.17 290 0.2702 1600 5900 23.0×10 -6
Beetle 100 19/2.67 106.0 13.4 293 0.2704 1742 5600 23.0×10 -6
Bee 125 7/4.90 132.0 14.7 361 0.2169 1944 5600 23.0×10 -6
Cricket 150 7/5.36 157.9 16.1 432 0.1818 2385 5600 23.0×10 -6
Hornet 150 19/3.25 157.6 16.25 434 0.1825 2570 5600 23.0×10 -6
Caterpillar 175 19/3.53 186 17.7 512 0.1547 2863 5600 23.0×10 -6
Chafer 200 19/3.78 213.2 18.9 587 0.1349 3240 5600 23.0×10 -6
Spider 225 19/3.99 236.9 20.0 652 0.1211 3601 5600 23.0×10 -6
Cockroach 250 19/4.22 265.7 21.10 731 0.1083 4040 5600 23.0×10 -6
Butterfly 300 19/4.65 322.7 23.25 888 0.08916 4875 5600 23.0×10 -6
Moth 350 19/5.00 373.2 25.0 1027 0.07711 5637 5600 23.0×10 -6
Drone 350 37/3.58 373.3 25.1 1029 0.07741 5745 5600 23.0×10 -6
Locust 400 19/5.36 428.5 26.8 1179 0.06710 6473 5600 23.0×10 -6
Centipede 400 37/3.78 415.2 26.46 1145 0.06944 6310 5600 23.0×10 -6
Maybug 450 37/4.09 486.9 28.6 1342 0.05931 7401 5600 23.0×10 -6
Scorpion 500 37/4.27 529.5 29.9 1460 0.05441 7998 5600 23.0×10 -6
Cicada 600 37/4.65 628.6 32.6 1733 0.04588 9495 5600 23.0×10 -6
Tarantula 750 37/5.23 794.6 36.6 2191 0.03627 12010 5600 23.0×10 -6

7.ASTM B231 Standard

Code word Size of
Conductor
Stranding and Wire Diameter Overall Diameter Max.D.C. Resistance at 20°C Code word Size of Conductor Stranding and Wire Diameter Overall Diameter Max.D.C. Resistance at 20°C
AWG or MCM mm mm ohm/km AWG or MCM mm mm ohm/km
Peachbell 6 7/1.554 4.67 2.1692 Verbena 700 37/3.493 24.45 0.0813
Rose 4 7/1.961 5.89 1.3624 Nasturtium 715.5 61/2.75 24.76 0.0795
Lris 2 7/2.474 7.42 0.8577 Violet 715.5 37/3.533 24.74 0.0795
Pansey 1 7/2.776 8.33 0.6801 Cattail 750 61/2.817 25.35 0.0759
Poppy 1/0 7/3.119 9.36 0.5390 Petunia 750 37/3.617 25.32 0.0759
Aster 2/0 7/3.503 10.51 0.4276 Lilac 795 61/2.90 26.11 0.0715
Phlox 3/0 7/3.932 11.80 0.3390 Arbutus 795 37/3.724 26.06 0.0715
Oxlip 4/0 7/4.417 13.26 0.2688 Snapdragon 900 61/3.086 27.78 0.0632
Valerian 250 19/2.913 14.57 0.2275 Cockscomb 900 37/3.962 27.73 0.0632
Sneezewort 250 7/4.80 14.4 0.2275 Goldenrod 954 61/3.177 28.6 0.0596
Laurel 266.8 19/3.01 15.05 0.2133 Magnolia 954 37/4.079 28.55 0.0596
Daisy 266.8 7/4.96 14.9 0.2133 Camellia 1000 61/3.251 29.36 0.0569
Peony 300 19/3.193 15.97 0.1896 Hawkweed 1000 37/4.176 29.23 0.0569
Tulip 336.4 19/3.381 16.91 0.1691 Larkspur 1033.5 61/3.307 29.76 0.0550
Daffodil 350 19/3.447 17.24 0.1625 Bluebell 1033.5 37/4.244 29.72 0.0550
Canna 397.5 19/3.673 18.36 0.1431 Marigold 1113 61/3.432 30.89 0.0511
Goldentuft 450 19/3.909 19.55 0.1264 Hawthorn 1192.5 61/3.551 31.05 0.0477
Syringa 477 37/2.882 20.19 0.1193 Narcissus 1272 61/3.668 33.02 0.0477
Cosmos 477 19/4.023 20.12 0.1193 Columbine 1351.5 61/3.78 34.01 0.0421
Hyacinth 500 37/2.951 20.65 0.1138 Carnation 1431 61/3.89 35.03 0.0398
Zinnia 500 19/4.12 20.6 0.1138 Gladiolus 1510.5 61/4.00 35.09 0.0376
Dahlia 556.5 19/4.346 21.73 0.1022 Coreopsis 1590 61/4.099 36.51 0.03568
Mistletoe 556.5 37/3.114 21.79 0.1022 Jessamine 1750 61/4.302 38.72 0.0325
Meadowsweet 600 37/3.233 22.63 0.0948 Cowslip 2000 91/3.76 41.40 0.02866
Orchid 636 37/3.33 23.31 0.0894 Lupine 2500 91/4.21 46.30 0.0230
Heuchera 650 37/3.366 23.56 0.0875 Trillium 3000 127/3.90 50.75 0.0192
Flag 700 61/2.72 24.48 0.0813 Bluebonnet 3500 127/4.21 54.80 0.01653

 

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.