33kv 2xsyr (a) O Single Core XLPE Copper Cable 630sqmm

 33kv 2xsyr (a) O Single Core XLPE Copper Cable 630sqmm

Produktdetails

Basis Info

Modell Nr.:yjsv72
Anwendung: Bau , U-Bahn , Kraftwerk
Spannung: Nieder-und Mittelspannung Kabel
Strom: DC & AC
Isoliermaterial: XLPE
Mantelmaterial: PVC
Material Form: Runddraht
Draht Kernmaterial: Blanken Kupferdraht
Bescheinigung: ISO , CCC , CE , VDE

Zusätzliche Informationen.

Warenzeichen:Yifang
Verpackung:Steel-Wooden Drum
Standard:1x630mm2
Herkunft:P. R. China
HS-Code:8544492100

Produktbeschreibung

5~46KV XLPE insulated power cable
1. Brief of Description
     Cross-linked polyethylene insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat aging and environmental stress. Its structure is simple. The long term operating temperature is 90oC. It is convenient to use and can be laid with no restriction of different level.
     Our enterprise can produce both flame retardant and non-flame retardant series of XLPE power cable.
     Our XLPE power cable can be produced according to your specifications, which are equivalent to IEC, DIN, BS and ASTM, and some indexes are superior to standards stated above.
     The flame-retardant cable covers all kinds of low-smoke low-halogen, low-smoke halogen free and three classes of A, B, C.
     We can design and manufacture special XLPE cable according to other standards required by the customers, such as Heavy section cut apart conductors, water-resistance, defend termites, defend mouse and so on.
 
2. Service conditions and operation parameters of cable
   A) Max. conductor operating temperature: 90oC
   B) Short circuit temperature: 250oC
   C) Ambient temperature: 30oC
   D) Soil temperature: 20oC
   E) Depth of laying in direct: 0.8m
   F) Thermal resistance of soil: 150oC.cm/W
   G) Thermal resistance of ducts: 120oC.cm/W
 
3. Application and Main type
 

Type Description Main Application
Copper Conductor Aluminum Conductor
YJV
Cu/XLPE/PVC
YJLV
Al/XLPE/PVC
Copper or aluminum conductor
XLPE insulated, Copper tape
screen PVC sheathed power cable
For laying indoor, tunnel, underground and cannel.
Unable to bear external mechanical pulling force and pressure during laid.
YJV
Cu/XLPE/L(H)DPE
YJLV
Al/XLPE/L(H)DPE
Copper or aluminum conductor 
XLPE insulated, Copper tape screen
PE/LDPE/HDPE sheathed power cable
YJE
Cu/XLPE/LSOH
YJLE
Al/XLPE/LSOH
Copper or aluminum conductor XLPE
insulated, Copper tape
screen LSOH sheathed power cable
YJSV
Cu/XLPE/CWS/PVC
N2XS(SE)Y
YJLSV
Al/XLPE/CWS/PVC
N2XS(SE)Y
Copper or aluminum conductor XLPE
insulated, Copper wire+ Copper tape
screen PVC sheathed power cable
   
For laying indoor, tunnel, underground and cannel.
Unable to bear external mechanical pulling force and pressure during laid, fault current requires large.
CWS(Copper wire screen)
type: A: Fixed section 
B: Full/one third/one sixth/one eighth/one sixteenth neutral
YJSY
Cu/XLPE/CWS/L(M.H)DPE
N2XS(SE)2Y
 
YJLSY
Al/XLPE/CWS/L(M.H)DPE
N2XS(SE)2Y
Copper or aluminum conductor XLPE
insulated, Copper wire+ Copper tape
screen PE/LDPE/HDPE sheathed power cable
YJE
Cu/XLPE/CWS/LSOH
YJLE
Al/XLPE/CWS/LSOH
Copper or aluminum conductor XLPE
Copper wire+ Copper tape
screen LSOH sheathed power cable
YJV22
Cu/XLPE/STA/PVC
YJLV22
Al/XLPE/STA/PVC
Copper or aluminum conductor XLPE
insulated, Copper tape screen, steel tape armored, PVC sheathed power cable
   
For laying indoor, tunnel, underground and cannel.
Able to bear external mechanical forces, but unable to bear large pulling force.
YJV23
Cu/XLPE/STA/L(M.H)PE
YJLV23
Al/XLPE/STA/L(M.H)PE
Copper or aluminum conductor XLPE
insulated, Copper tape screen, steel tape armored, PE/LDPE/HDPE sheathed power cable
WD-YJY23
Cu/XLPE/STA/LSOH
WD-YJLY23
Al/XLPE/STA/LSOH
Copper or aluminum conductor XLPE insulated, Copper tape screen, steel tape armored, PVC sheathed power cable
 
YJSV22
Cu/XLPE/CWS/STA/PVC
N2XSEBY
YJLSV22
Al/XLPE/CWS/STA/PVC
N2XSEBY
Copper or aluminum conductor XLPE insulated,
Copper wire+ Copper tape screen, steel tape armored, PVC sheathed power cable
 
For laying indoor, tunnel, underground and cannel.
Able to bear external mechanical forces, but unable to bear large pulling force. fault current requires large.
CWS(Copper wire screen)
type: A: Fixed section 

 
 
 

Type Description Main Application
Copper Conductor Aluminum Conductor
YJSV23
Cu/XLPE/CWS/STA
L(M.H)PE
N2XSEB2Y
YJLSV23
Al/XLPE/CWS/STA
L(M.H)PE
NA2XSEB2Y
Copper or aluminum conductor XLPE insulated, copper wire+ copper tape screen, steel tape armored, PE/LDPE/HDPE sheathed power cable For laying indoor, tunnel, underground and canal. Able to bear external mechanical forces, but unable to bear large pulling force. fault current requires large.
CWS(Copper wire screen) tape: Fixed section
WD-YJSY23
Cu/XLPE/CWS/STA/LSOH
WD-YJLSY23
Al/XLPE/CWS/STA/LSOH
Copper or aluminum conductor XLPE insulated, copper wire+ copper tape screen, steel tape armored, LOSH sheathed power cable
YJV32
Cu/XLPE/SWA/PVC
YJLV32
Al/XLPE/SWA/PVC
Copper or aluminum conductor XLPE INSULATED, Copper tape screen, galvanized steel wire armored, PVC sheathed power cable. For laying in shaft, water under ground and large difference of level, able to bear external mechanical pressure and moderate pulling force.
YJV33
Cu/XLPE/SWA/L(M.H)PE
YJLV33
Al/XLPE/SWA/L(M.H)PE
Copper or aluminum conductor XLPE insulated, copper tape screen, galvanized steel wire armored, PE/LDPE/HDPE sheathed power cable
WD-YJY33
Cu/XLPE/SWA/LSOH
WD-YJLY33
Al/XLPE/SWA/LSOH
Copper or aluminum conductor XLPE insulated, copper tape screen, galvanized steel wire armored, LSOH sheathed power cable.
YJSV32
Cu/XLPE/CWS/SWA/PVC
N2XSWRY
YJLSV32
Al/XLPE/CWS/SWA/PVC
NA2XSWRY
 Copper or aluminum conductor XLPE insulated, copper wire+ copper tape screen, galvanized steel wire armored, PVC sheathed power cable  For laying in shaft, water under ground and large differnce of level, able to bear extenal mechanical pressure and moderate pulling force. fault current requires large.
CWS(Copper wire screen) tape: Fixed section
YJSV33
Cu/XLPE/CWS/SWA/L(M.H)PE
N2XSER2Y
YJLSV33
Al/XLPE/CWS/SWA/L(M.H)PE
NA2XSER2Y
Copper or aluminum conductor XLPE insulated, copper wire+ copper tape screen, galvanized steel wire armored, PE/LDPE/HDPE sheathed power cable
WD-YJY33
Cu/XLPE/SWA/LSOH
WD-YJLY33
Al/XLPE/SWA/LSOH
Copper or aluminum conductor XLPE insulated, copper wire+ copper tape screen, galvanized steel wire armored, LSOH sheathed power cable

 
4. Scope of voltage grade and core number and cross-section
 
   a) National standard

Rated voltage(KV) 3.6/6 6/6 6/10 8.7/10 8.7/15 12/15 12/20 18/20 18/30 21/35 26/35
Core Number 1 core, 3 core
Cross-section
mm2
1C 25~800 35~800
3C 25~400 35~400

 
b) IEC/BS/DIN standard

Rated voltage(KV) 3.6/6 6/6 6/10 8.7/10 8.7/15 12/15 12/20 18/20 18/30 21/35 26/35
Core Number 1 core, 3 core
Cross-section
mm2
1C 25~800 35~800
3C 25~400 35~400

 
  c) ASTM standard

Rated voltage(KV) 5001-8000 8001-15000 15001-25000 25001-28000 28001-35000 35001-46000
  1 core, 3 core
Cross-section
mm2
1C
 
6AWG~1600kcmil 2AWG~1600kcmil 1AWG~1600kcmil 2AWG~1600kcmil 1/0AWG~1600kcmil
 
3C
6AWG~1600kcmil 2AWG~1600kcmil 1AWG~1600kcmil 2AWG~1600kcmil 4/0AWG~1600kcmil

 
 
 
 
 
 
 
5. D.C Resistance of finished cable at 20oC per km is not more than following:
 

Nominal Cross-section
mm2
25 35 50 70 95 120 150 185 240 300
20oC DC Resistance
Ω/km
Cu 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601
Al 1.2 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100
Nominal Cross-section
mm2
400 500 630 800 1000 1200 1400 1600 1800 2000
20oC DC Resistance
Ω/km
Cu 0.0470 0.0366 0.0283 0.0221 0.0176 0.0151 0.0123 0.0108 0.0096 0.0086
Al 0.0778 0.0605 0.0469 0.0367 0.0291 0.0247 0.0202 0.0177 0.0157  
Nominal Cross-section
AWG
6 5 4 3 2 1 1/0 2/0 3/0 4/0
20oC DC Resistance
Ω/km
Cu 1.3219 1.0453 0.8298 0.6594 0.5211 0.4149 0.3281 0.2605 0.2065 0.1640
Al 2.1699 1.7167 1.3631 1.0802 0.8551 0.6783 0.5401 0.4276 0.3376 0.2688
Nominal Cross-section
MCM
250 300 350 400 450 500 550 600 650 700
20oC DC Resistance
Ω/km
Cu 0.1386 0.1158 0.0991 0.0865 0.0772 0.0695 0.0630 0.0579 0.0534 0.0495
Al 0.2273 0.1897 0.1623 0.1421 0.1263 0.1138 0.1032 0.0948 0.0874 0.0813
Nominal Cross-section
MCM
750 800 900 1000 1100 1200 1300 1400 1500 1600
20oC DC Resistance
Ω/km
Cu 0.0463 0.0434 0.0386 0.0347 0.0316 0.0289 0.0237 0.0248 0.0231 0.0217
Al 0.0759 0.0711 0.0630 0.0569 0.0518 0.0473 0.0437 0.0405 0.0379 0.0357

 
 

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.

Ähnlich oder verwandt