China Hochwertiger Aluminiumleiter, XLPE Isolations-ABC-Kabel, Antennenkabel, Servicekabel


                                 China Hochwertiger Aluminiumleiter, XLPE Isolations-ABC-Kabel, Antennenkabel, Servicekabel

Basis Info

Modell Nr..
ABC Cable

Art
Isolierte

Leitertyp
Stranded

Anwendung
Oben ,
U-Bahn

Leitermaterial
Aluminium

Isoliermaterial
XLPE

Material Form
Runddraht

Bescheinigung
ISO9001 ,
CE ,
CCC ,
RoHS

Zusätzliche Informationen.

Warenzeichen
Huatong

Verpackung
All Wooden, Steel Wooden or Steel Package

Herkunft
China

HS-Code
8544492100

Produktionskapazität
5000tons /Month

Produktbeschreibung


ABC cable is suitable for transmitting line and distributing line of rated voltage 0.6/1KV and others.It is widely used at tall buildings,traveling development area and rural area or other place the cost of underground network is expensive.
 

Basic Information
Code Name
ABC
Rated Voltage (Uo/U)
0.6/1KV
Temperature Range
-15ºC-90ºC

—————————————————————————————————————————–

CONSTRUCTION
Conductor: Copper or Aluminium
Insulation: XLPE
Normally,ABC Cable(ABC Bundled Cable-Aerial Cable) do not use copper,because Aluminium Cost is high,most of our customers use aluminium.
—————————————————————————————————————————–

CABLE STANDARDS
Chinese National Standards, IEC,SANS 1418-1, SANS1418-2, ASTMB230, ASTMB231,ASTM B398,ASTM B399, NF C33-209 and etc. upon request.

—————————————————————————————————————————–

Aerial Bundle Conductor-ABC(South Africa Standard Sizes)-SANS 1418-1

Table 01 Aerial Bundled Cable-ABC-AS NZS 3506.1
 

1+1 Structure
Phase Conductor Neutral Conductor Completed Cable
Section Insulation Thickness Minimum number of wires Max. dc resistance at 20°C Section Insulation Thickness Minimum number of wires Max. dc resistance at 20°C Minimum breaking load Approx. Overall Diameter Approx. Weight Of Cable
mm2 mm No. ohm/km mm2 mm No. ohm/km KN mm Kg/km
1×16 1.3 6 1.91 1×16 1.3 6 1.91 4.4 15.0 140
1×25 1.3 6 1.20 1×25 1.3 6 1.20 7.0 17.6 210
1×35 1.5 6 0.868 1×35 1.5 6 0.868 9.8 19.6 270
1×50 1.5 6 0.641 1×50 1.5 6 0.641 14.0 22.8 370
1×95 1.7 15 0.320 1×95 1.7 15 0.320 26.6 30.6 680
2+1 Structure
Phase Conductor Neutral Conductor Completed Cable
Section Insulation Thickness Minimum number of wires Max. dc resistance at 20°C Section Insulation Thickness Minimum number of wires Max. dc resistance at 20°C Minimum breaking load Approx. Overall Diameter Approx. Weight Of Cable
mm2 mm No. ohm/km mm2 mm No. ohm/km KN mm Kg/km
2×25 1.3 6 1.20 1×25 1.3 6 1.20 10.5 19.0 310
2×35 1.3 6 0.868 1×35 1.3 6 0.868 14.7 21.1 410
2×50 1.5 6 0.641 1×50 1.5 6 0.641 21.0 24.6 550
3+1 Structure
Phase Conductor Neutral Conductor Completed Cable
Section Insulation Thickness Minimum number of wires Max. dc resistance at 20°C Section Insulation Thickness Minimum number of wires Max. dc resistance at 20°C Minimum breaking load Approx. Overall Diameter Approx. Weight Of Cable
3×16 1.3 6 1.91 1×16 1.3 6 1.91 8.8 18.1 290
3×25 1.3 6 1.20 1×25 1.3 6 1.20 14.0 21.2 410
3×35 1.3 6 0.868 1×35 1.3 6 0.868 19.6 23.7 550
3×50 1.5 6 0.641 1×50 1.5 6 0.641 28.0 27.5 740
3×70 1.5 12 0.443 1×70 1.5 12 0.443 39.2 31.9 1000
3×95 1.7 15 0.320 1×95 1.7 15 0.320 53.2 36.9 1370
3×120 1.7 15 0.253 1×120 1.7 15 0.253 67.2 40.6 1690
3×150 1.7 15 0.206 1×150 1.7 15 0.206 84.0 43.9 2020

 

 

BS7884-1997

Nominal Area

Stranding

Diameter of conductor

Linear mass

Rated strength

D.C. resistance at 20°C

mm2

No./mm

mm

Kg/km

KN

Ω/km

10

7/1.35

4.05

89.82

3.752

1.829

14

7/1.6

4.8

126.2

5.627

1.30300

16

3/2.65

5.72

148.30

6.194

1.10600

16

7/1.7

5.10

142.40

5.946

1.15400

25

7/2.1

6.30

217.30

9.073

0.75630

32

3/3.75

8.10

296.90

12.4

0.55200

32

7/2.46

7.38

298.20

12.442

0.54970

35

7/2.5

7.50

308.00

12.86

0.53370

50

7/3.00

9.00

443.50

18.52

0.37060

50

19/1.8

9.00

435.80

17.7

0.38190

70

7/3.55

10.65

621.10

25.93

0.26460

70

19/2.1

10.50

593.20

24.09

0.28060

95

19/2.5

12.50

840.70

34.14

0.19800

100.0

7/4.3

12.90

911.20

36.54

0.18100

120.0

19/2.8

14.00

1055.00

42.83

0.15780

125.0

19/2.9

14.50

1131.00

45.94

0.14710

150.0

19/3.2

16.00

1377.00

55.94

0.12080

150.0

37/2.25

15375.00

1334.00

53.88

0.12640

185.0

19/3.55

17.75

1695.00

68.86

0.09815

185.0

37/2.5

17.75

1647.00

66.49

0.10240

Phase Phase Phase Approx.Overall Diameter Max. D.C. Resistance of Conductor at 20 Centigrade
AAC+UV-XLPE Compact Conductor UV-XLPE Insulation
No.X Normal Cross Section of Cores No.of Al Wires Overall Diameter Normal Thickness Min. Diameter
No. X mm 2 mm mm mm mm mm ohm/km
1 X 10 7 4.05 1.0 0.8 6.05 6.05 3.08
1 X 16 7 4.8 1.2 0.98 7.2 7.20 1.91
1 X 25 7 6 1.2 0.98 8.4 8.40 1.20
1 X 35 7 7.0 1.4 1.16 9.8 9.80 0.868
1 X 50 7 8.3 1.4 1.16 11.1 11.10 0.641
1 X 70 19 9.8 1.4 1.16 12.6 12.60 0.443
1 X 95 19 11.6 1.6 1.34 14.8 14.80 0.320
1 X 120 19 13 1.6 1.34 16.2 16.20 0.253
1 X 150 19 14.6 1.8 1.52 18.2 18.20 0.206
1 X 185 36 16.2 2.0 1.70 20.2 20.20 0.164
1 X 240 36 18.4 2.2 1.88 22.8 22.80 0.125
2 X 10 7 4.05 1.0 0.8 6.05 12.10 3.08
2 X 16 7 4.8 1.2 0.98 7.2 14.40 1.91
2 X 25 7 6 1.2 0.98 8.4 16.80 1.20
2 X 35 7 7.0 1.4 1.16 9.8 19.60 0.868
2 X 50 7 8.3 1.4 1.16 11.1 22.20 0.641
2 X 70 19 9.8 1.4 1.16 12.6 25.20 0.443
2 X 95 19 11.6 1.6 1.34 14.8 29.60 0.320
2 X 120 19 13 1.6 1.34 16.2 32.40 0.253
2 X 150 19 14.6 1.8 1.52 18.2 36.40 0.206
2 X 185 36 16.2 2.0 1.70 20.2 40.40 0.164
2 X 240 36 18.4 2.2 1.88 22.8 45.60 0.125
3 X 10 7 4.05 1.0 0.8 6.05 13.07 3.08
3 X 16 7 4.8 1.2 0.98 7.2 15.55 1.91
3 X 25 7 6 1.2 0.98 8.4 18.14 1.20
3 X 35 7 7.0 1.4 1.16 9.8 21.17 0.868
3 X 50 7 8.3 1.4 1.16 11.1 23.98 0.641
3 X 70 19 9.8 1.4 1.16 12.6 27.22 0.443
3 X 95 19 11.6 1.6 1.34 14.8 31.97 0.320
3 X 120 19 13 1.6 1.34 16.2 34.99 0.253
3 X 150 19 14.6 1.8 1.52 18.2 39.31 0.206
3 X 185 36 16.2 2.0 1.70 20.2 43.63 0.164
3 X 240 36 18.4 2.2 1.88 22.8 49.25 0.125
4 X 10 7 4.05 1.0 0.8 6.05 14.64 3.08
4 X 16 7 4.8 1.2 0.98 7.2 17.42 1.91
4 X 25 7 6 1.2 0.98 8.4 20.33 1.20
4 X 35 7 7.0 1.4 1.16 9.8 23.72 0.868
4 X 50 7 8.3 1.4 1.16 11.1 26.86 0.641
4 X 70 19 9.8 1.4 1.16 12.6 30.49 0.443
4 X 95 19 11.6 1.6 1.34 14.8 35.82 0.320
4 X 120 19 13 1.6 1.34 16.2 39.20 0.253
4 X 150 19 14.6 1.8 1.52 18.2 44.04 0.206
4 X 185 36 16.2 2.0 1.70 20.2 48.88 0.164
4 X 240 36 18.4 2.2 1.88 22.8 55.18 0.125

 