AAC-Leiter, Blank, Leiter BS215, Wesp, Schmetterling, Ant Mosquito


                                 AAC-Leiter, Blank, Leiter BS215, Wesp, Schmetterling, Ant Mosquito

Basis Info

Modell Nr..
35mm2 50mm2 100mm2

Art
Blank

Leitertyp
Stranded

Anwendung
Oben

Leitermaterial
Aluminium

Isoliermaterial
Blank

Material Form
Runddraht

Bescheinigung
ISO9001 ,
CCC

Zusätzliche Informationen.

Warenzeichen
Huatong

Verpackung
Wood Drum or Steel-Wood Drum

Standard
Aluminium 1350-H19

Herkunft
China

HS-Code
7614900000

Produktionskapazität
5000ton/Month

Produktbeschreibung

AAC wire bare conductor BS215 Wasp Butterfly Ant Mosquito

Construction:
Aluminum 1350 wires are concentrically stranded and wrapped helically around a central wire. Each successive layer has six wires more than the previous underlying layer. Outer layer is right hand lay and reversed in successive layers. AAC(All aluminum conductor) is the most economical bare overhead conductor due to its lighter weight. It offers easier handing during installation and use of simpler fittings. The conductor is corrosion resistant due to its homogeneous construction.

Bare Conductor Types
(1) all aluminum conductor (AAC)
(2) all aluminum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminum conductor aluminum clad steel reinforced(ACSR/AW)
(6)rear earth aluminum conductor steel reinforced(ACSR/RE)
(7)aluminum conductor aluminum alloy reinforced(ACAR)

If your have any interested products, Please feel free to contact our sales team.
 

ASTM B230,B231,B400 Standards

Code name Nominal
aluminum
area
Stranding
and wire
diameter
Sectional
area
Overall
diameter
Linear
mass
Max. DC
resistance
at 20 ºC
Rated strength Final
modulus
of elasticity
Coefficient
of linear
expansion
mm 2 mm mm 2 mm kg/km Ω/km daN hbar /ºC
Midge 22 7/2.06 23.33 6.18 63.8 1.227 399 5900 23.0×10 -6
Aphis 25 3/3.35 26.40 7.2 73 1.081 411 5900 23.0×10 -6
Gnat 25 7/2.21 26.8 6.6 73 1.066 459 5900 23.0×10 -6
Weevil 30 3/3.66 31.6 7.9 86 0.9082 486 5900 23.0×10 -6
Mosquito 35 7/2.59 37.0 7.8 101 0.7762 603 5900 23.0×10 -6
Ladybird 40 7/2.79 42.8 8.4 117 0.6689 687 5900 23.0×10 -6
Ant 50 7/3.10 52.83 9.30 145 0.5419 828 5900 23.0×10 -6
Fly 60 7/3.40 63.55 10.20 174 0.4505 990 5900 23.0×10 -6
Bluebottle 70 7/3.66 73.7 11.0 202 0.3881 1134 5900 23.0×10 -6
Earwig 75 7/3.78 78.5 11.4 215 0.3644 1194 5900 23.0×10 -6
Grasshopper 80 7/3.91 84.1 11.7 230 0.3406 1278 5900 23.0×10 -6
Clegg 90 7/4.17 95.6 12.5 262 0.2994 1453 5900 23.0×10 -6
Wasp 100 7/4.39 106.0 13.17 290 0.2702 1600 5900 23.0×10 -6
Beetle 100 19/2.67 106.0 13.4 293 0.2704 1742 5600 23.0×10 -6
Bee 125 7/4.90 132.0 14.7 361 0.2169 1944 5600 23.0×10 -6
Cricket 150 7/5.36 157.9 16.1 432 0.1818 2385 5600 23.0×10 -6
Hornet 150 19/3.25 157.6 16.25 434 0.1825 2570 5600 23.0×10 -6
Caterpillar 175 19/3.53 186 17.7 512 0.1547 2863 5600 23.0×10 -6
Chafer 200 19/3.78 213.2 18.9 587 0.1349 3240 5600 23.0×10 -6
Spider 225 19/3.99 236.9 20.0 652 0.1211 3601 5600 23.0×10 -6
Cockroach 250 19/4.22 265.7 21.10 731 0.1083 4040 5600 23.0×10 -6
Butterfly 300 19/4.65 322.7 23.25 888 0.08916 4875 5600 23.0×10 -6
Moth 350 19/5.00 373.2 25.0 1027 0.07711 5637 5600 23.0×10 -6
Drone 350 37/3.58 373.3 25.1 1029 0.07741 5745 5600 23.0×10 -6
Locust 400 19/5.36 428.5 26.8 1179 0.06710 6473 5600 23.0×10 -6
Centipede 400 37/3.78 415.2 26.46 1145 0.06944 6310 5600 23.0×10 -6
Maybug 450 37/4.09 486.9 28.6 1342 0.05931 7401 5600 23.0×10 -6
Scorpion 500 37/4.27 529.5 29.9 1460 0.05441 7998 5600 23.0×10 -6
Cicada 600 37/4.65 628.6 32.6 1733 0.04588 9495 5600 23.0×10 -6
Tarantula 750 37/5.23 794.6 36.6 2191 0.03627 12010 5600 23.0×10 -6

——————————————-We also can products related aluminium conductor———————————–

ACSR Technical Characteristics Based on Standard BS 215-2   
 

Code name Nominal aluminium area Stranding and wire     diameter Sectional area of aluminium Total sectional area Approx. overall diameter Approx. mass Calculated D.C. resistance at 20oC Calculated breaking load
Al Steel
mm2 No./mm mm2 mm2 mm kg/km Ω/km kN
RABBIT 50 6/3.35 1/3.35 52.88 61.7 10.05 214 0.5426 18.35
DOG 100 6/4.72 7/1.57 105 118.5 14.15 394 0.2733 32.7
WOLF 150 30/2.59 7/2.59 158.1 194.9 18.13 726 0.1828 69.2
DINGO 150 18/3.35 1/3.35 158.7 167.5 16.75 506 0.1815 35.7
LYNX 175 30/2.79 7/2.79 183.4 226.2 19.53 842 0.1576 79.8
ZEBRA 400 54/3.18 7/3.18 428.9 484.5 28.62 1621 0.0674 131.9

 
 
 AAAC Technical Characteristics Based on Standard BS 3242  
 

Code name Nominal aluminium area Stranding and wire     diameter Sectional area Approx. overall diameter Approx. mass Calculated D.C. resistance at 20oC Calculated breaking load
mm2 No./mm mm2 mm kg/km Ω/km kN
ALMOND 25 7/2.34 30.1 7.02 82 1.094 8.44
CEDAR 30 7/2.54 35.47 7.62 97 0.9281 9.94
FIR 40 7/2.95 47.84 8.85 131 0.688 13.4
HAZEL 50 7/3.30 59.87 9.9 164 0.5498 16.8
OAK 100 7/4.65 118.9 13.95 325 0.2769 33.3
ASH 150 19/3.48 180.7 17.4 497 0.183 50.65
ELM 175 19/3.76 211 18.8 580 0.1568 59.1
UPAS 300 37/3.53 362.1 24.71 997 0.09155 101.5

 