ACSR (Aluminum Conductor Steel Reinforced) for DIN Standard

 ACSR (Aluminum Conductor Steel Reinforced) for DIN Standard

Produktdetails

Basis Info

Modell Nr.:16/2.5mm2, 25/4mm2, 35/6mm2, 44/32mm2, 50/8mm2
Art: Blank
Leitertyp: Stranded
Anwendung: Oben
Leitermaterial: Aluminium
Isoliermaterial: Blank
Bescheinigung: ISO9001 , CE

Zusätzliche Informationen.

Warenzeichen:Jiapu
Verpackung:Drums
Standard:CE SGS SABS
Herkunft:HENAN CHINA
HS-Code:8544492100
Produktionskapazität:2000ton/Month

Produktbeschreibung

ACSR

IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110 standard

ISO 9001 and ISO 14001. CE, SONCAP certificate

AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels.

Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.

1. Specification:
(1) All aluminium conductor (AAC)
(2) All aluminimum alloy conductor(AAAC)
(3) Aluminum conductor steel reinforced (ACSR)
(4) Anti-corrosion type ACSR
(5) Aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6) Rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7) Aluminimum conductor aluminimum alloy reinforced(ACAR)

2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM

(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C
Galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)

B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)

B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)

B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.

Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Specification

Code Number Calculated Cross Section No./Dia. Of Stranding Wires Overall
Diameter
Linear Mass Nominal Breaking Load Max.D.C. Resistance
at 20ºC
Al./St Al. Steel Total Alum. Steel Alum. Steel Total
mm² mm² mm² mm² mm mm mm kg/km kg/km kg/km daN Ω/km
16/2.5 15.3 2.5 17.8 6/1.80 1/1.80 5.4 42 20 62 595 1.878
25/4 23.8 4 27.8 6/2.25 1/2.25 6.8 65 32 97 920 1.2002
35/6 34.3 5.7 40 6/2.70 1/2.70 8.1 94 46 140 1265 0.8352
44/32 44 31.7 75.7 14/2.00 7/2.40 11.2 122 250 372 4500 0.6573
50/8 48.3 8 56.3 6/3.20 1/3.20 9.6 132 64 196 1710 0.5946
50/30 51.2 29.8 81 12/2.33 7/2.33 11.7 141 237 378 4380 0.5643
70/12 69.9 11.4 81.3 26/1.85 7/1.44 11.7 193 91 284 2680 0.413
95/15 94.4 15.3 109.7 26/2.15 7/1.67 13.6 260 123 383 3575 0.3058
95/55 96.5 56.3 152.8 12/3.20 7/3.20 16 266 446 712 7935 0.2992
105/75 106 75.5 181.5 14/3.10 9/2.25 17.5 292 599 891 10845 0.2735
120/20 121 19.8 141.4 26/2.44 7/1.90 15.5 336 158 494 4565 0.2374
120/70 122 71.3 193.3 12/3.6 7/3.60 18 337 564 901 10000 0.2364
125/30 128 29.8 157.7 30/2.33 7/2.33 16.3 353 238 591 5760 0.2259
150/25 149 24.2 173.1 26/2.70 7/2.10 17.1 411 194 605 5525 0.1939
170/40 172 40.1 211.9 30/2.70 7/2.70 18.9 475 319 794 7675 0.1682
185/30 184 29.8 213.6 26/3.00 7/2.33 19 507 239 746 6620 0.1571
210/35 209 34.1 243.2 26/3.20 7/2.49 20.3 577 273 850 7490 0.138
210/50 212 49.5 261.6 30/3.00 7/3.00 21 587 394 981 9390 0.1362
230/30 231 29.8 260.7 24/3.50 7/2.33 21 638 239 877 7310 0.1249
240/40 243 39.5 282.5 26/3.45 7/2.68 21.9 671 316 987 8640 0.1188
265/35 264 34.1 297.8 24/3.74 7/2.49 22.4 728 274 1002 8305 0.1094
300/50 304 49.5 353.7 26/3.86 7/3.00 24.5 840 396 1236 10700 0.09487
305/40 305 39.5 344.1 54/2.68 7/2.68 24.1 843 317 1160 9940 0.0949
340/30 339 29.8 369.1 48/3.00 7/2.33 25 938 242 1180 9290 0.08509
380/50 382 49.5 431.5 54/3.00 7/3.00 27 1056 397 1453 12310 0.08509
385/35 386 34.1 420.1 48/3.20 7/2.49 26.7 1067 277 1344 10480 0.07573
435/55 434 59.3 490.6 54/3.20 7/3.20 28.8 1203 450 1653 13645 0.07478
450/40 449 39.5 488.2 48/3.45 7/2.68 28.7 1241 320 1561 12075 0.06656
490/65 490 63.6 553.9 54/3.40 7/3.40 30.6 1356 510 1866 15310 0.06434
495/35 494 34.1 528.2 45/3.74 7/2.49 29.9 1363 283 1646 12180 0.05846
510/45 510 45.3 555.5 48/3.68 7/2.87 30.7 1413 365 1778 13665 0.05655
550/70 550 71.3 621.3 54/3.60 7/3.60 32.4 1520 572 2092 17060 0.05259
560/50 562 49.5 611.2 48/3.86 7/3.00 32.2 1553 401 1954 14895 0.0514
570/40 566 39.5 610.3 45/4.02 7/2.68 32.2 1563 325 1888 13900 0.05108
650/45 699 45.3 653.5 45/4.30 7/2.87 34.4 1791 372 2163 15552 0.0442
680/85 679 86 764.8 54/4.00 19/2.40 36 1868 702 2570 21040 0.0426
1045/45 1046 45.3 1091 72/4.30 7/2.87 43 2879 370 3249 21787 0.0277