Aluminium-Clad Steel Wire (ACS Draht)
Produktdetails
Basis Info
Zusätzliche Informationen.
Produktbeschreibung
Aluminum-Clad Steel wire -ACS wire
Specifications:
A high strength steel wire with a 25% thick cross-section ratio of aluminum cladding creating a high electrical conductivity, highly corrosive resistant and a thermal stability for high temperature operation and all with a lighter weight.
Applications:
To be used as a guy or " messenger" wire, and static wire in utility classifications, for overhead use.
Specifications:
ACS wire meets or exceeds the following ASTM specifications:
l ASTM B415
Nominal diameter |
Cross–section mm2 |
Min. tensile strength MPa |
Calculated breaking load kN |
Min. coating thickness mm |
Max. DC resistance at 20ºC Ω/km |
Approx. weight kg/km |
|
mm | AWG | ||||||
2.052 | 12 | 3.307 | 1340 | 4.5 | 0.103 | 25.64 | 21.80 |
2.304 | 11 | 4.169 | 1340 | 5.6 | 0.115 | 20.34 | 27.49 |
2.589 | 10 | 5.260 | 1340 | 7.1 | 0.130 | 16.12 | 34.66 |
2.904 | 9 | 6.633 | 1340 | 8.9 | 0.145 | 12.78 | 43.65 |
3.264 | 8 | 8.367 | 1340 | 11.2 | 0.163 | 10.14 | 55.14 |
3.477 | 7 | 9.495 | 1310 | 12.4 | 0.174 | 8.93 | 62.57 |
3.665 | 7 | 10.55 | 1280 | 13.5 | 0.183 | 8.04 | 69.48 |
3.934 | 6 | 12.16 | 1240 | 15.1 | 0.197 | 6.93 | 80.13 |
4.115 | 6 | 13.30 | 1210 | 16.0 | 0.206 | 6.38 | 87.62 |
4.392 | 5 | 15.15 | 1170 | 17.7 | 0.220 | 5.60 | 99.84 |
4.620 | 5 | 16.76 | 1140 | 19.1 | 0.231 | 5.06 | 110.50 |
4.775 | 4 | 17.91 | 1100 | 19.7 | 0.239 | 4.73 | 118.0 |
5.189 | 4 | 21.15 | 1070 | 22.6 | 0.259 | 4.01 | 139.34 |
Aluminum Clad Steel Stranded Conductor -ACS cable
Construction:
ACS cable is composed of aluminum clad steel. Concentric-lay-stranded conductors of aluminum-clad steel wires.
Properties:
ACS similar tensile strength as Guy wire but has superior corrosion resistance and enables much higher conductivity if needed.
Specifications:
ACS cables meets or exceeds the following ASTM specifications:
l ASTM B-416
American Standard ACS Cable
No./size of strands | Cross–section | No. of wires | Diameter | Approx. weight | Rated strength | Max. DC resistance at 20ºC |
|
Wire | Conductor | ||||||
AWG | mm2 | mm | mm | kg/km | kN | Ω/km | |
3 No. 5 | 50.32 | 3 | 4.62 | 9.96 | 334.1 | 54.42 | 1.6990 |
3 No. 6 | 39.80 | 3 | 4.11 | 8.87 | 265.0 | 45.74 | 2.1420 |
3 No. 7 | 31.65 | 3 | 3.67 | 7.90 | 210.1 | 38.36 | 2.7010 |
3 No. 8 | 25.10 | 3 | 3.26 | 7.03 | 166.7 | 32.06 | 3.4060 |
3 No. 9 | 19.90 | 3 | 2.91 | 6.26 | 132.2 | 25.43 | 4.2940 |
3 No. 10 | 15.78 | 3 | 2.59 | 5.58 | 104.8 | 20.16 | 5.4150 |
7 No. 5 | 117.40 | 7 | 4.62 | 13.90 | 781.1 | 120.27 | 0.7426 |
7 No. 6 | 93.10 | 7 | 4.11 | 12.40 | 619.5 | 101.14 | 0.9198 |
7 No. 7 | 73.87 | 7 | 3.67 | 11.00 | 491.1 | 84.81 | 1.1600 |
7 No. 8 | 58.56 | 7 | 3.26 | 9.78 | 389.6 | 70.88 | 1.4630 |
7 No. 9 | 46.44 | 7 | 2.91 | 8.71 | 308.9 | 56.20 | 1.8440 |
7 No. 10 | 36.83 | 7 | 2.59 | 7.76 | 245.1 | 44.58 | 2.3250 |
7 No. 11 | 29.21 | 7 | 2.30 | 6.91 | 194.4 | 35.35 | 2.9320 |
7 No. 12 | 23.16 | 7 | 2.05 | 6.16 | 154.2 | 28.03 | 3.6970 |
19 No. 5 | 318.70 | 19 | 4.62 | 23.10 | 2129.0 | 326.39 | 0.2698 |
19 No. 6 | 252.70 | 19 | 4.11 | 20.60 | 1688.0 | 274.55 | 0.3402 |
19 No. 7 | 200.40 | 19 | 3.67 | 18.30 | 1339.0 | 230.18 | 0.4290 |
19 No. 8 | 158.90 | 19 | 3.26 | 16.30 | 1062.0 | 192.41 | 0.5409 |
19 No. 9 | 126.10 | 19 | 2.91 | 14.50 | 842.0 | 152.58 | 0.6821 |
19 No. 10 | 99.96 | 19 | 2.59 | 12.90 | 667.7 | 121.00 | 0.8601 |
37 No. 5 | 620.60 | 37 | 4.62 | 32.30 | 4170.0 | 635.43 | 0.1394 |
37 No. 6 | 492.20 | 37 | 4.11 | 28.80 | 3307.0 | 534.85 | 0.1757 |
37 No. 7 | 390.30 | 37 | 3.67 | 25.70 | 2623.0 | 448.09 | 0.2216 |
37 No. 8 | 309.50 | 37 | 3.26 | 22.90 | 2080.0 | 374.67 | 0.2794 |
37 No. 9 | 245.50 | 37 | 2.91 | 20.30 | 1649.0 | 279.11 | 0.3523 |
37 No. 10 | 194.70 | 37 | 2.59 | 17.90 | 1308.0 | 235.61 | 0.4443 |