IEC-Norm ACSR, AAC, AAAC, Aacsr Blanke Leiter für Hochspannungsleitung
Basis Info
Modell Nr..
Aacsr Bare Conductors
Art
Isolierte
Leitertyp
Stranded
Anwendung
Oben
Leitermaterial
Aluminium
Isoliermaterial
Blank
Material Form
Runddraht
Bescheinigung
ISO9001 ,
CE ,
CCC
CE ,
CCC
Zusätzliche Informationen.
Warenzeichen
Huatong
Verpackung
All Wooden, Steel Wooden or Steel Package
Herkunft
China
HS-Code
76141000
Produktionskapazität
5000tons /Month
Produktbeschreibung
AACSR –Aluminium Alloy Conductor Steel Reinforced
Standard:ASTM B711, DIN 48206, IEC 61089, BS EN 50183,GB/T1179-2008
1.Construction
(1)AACSR is a concentrically stranded conductor composed of one or more layers of 6201 -T81 aluminum alloy wire stranded with a high-strength coated steel core. The core may be single wire or stranded depending on the size.
(2)The proportions of aluminum alloy and steel can be varied to obtain the relation between current carrying capacity and mechanical strength best suited to each application.
(3)Core wire for AACSR is available with Class A, B or C-galvanized; "aluminized" (AZ): or aluminum clad (AW).
(4)Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease.
2.Application
Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity, they are suitable for laying across rivers and valleys where special geographical teatures exist.
Standard:ASTM B711, DIN 48206, IEC 61089, BS EN 50183,GB/T1179-2008
1.Construction
(1)AACSR is a concentrically stranded conductor composed of one or more layers of 6201 -T81 aluminum alloy wire stranded with a high-strength coated steel core. The core may be single wire or stranded depending on the size.
(2)The proportions of aluminum alloy and steel can be varied to obtain the relation between current carrying capacity and mechanical strength best suited to each application.
(3)Core wire for AACSR is available with Class A, B or C-galvanized; "aluminized" (AZ): or aluminum clad (AW).
(4)Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease.
2.Application
Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity, they are suitable for laying across rivers and valleys where special geographical teatures exist.
IEC1089
Code Number (No.) |
Steel Ratio (%) |
Areas (mm²) |
No. Of wires (No.) |
Wire Dia (mm) |
Diameter (mm) |
Linear Mass (kg/km) |
Rated Strength (kN) |
D.C. Resistance (Ω/km) |
|||||
Al | St | Total | Al | St | Al | St | Core | Conductor | |||||
16 | 17 | 18.6 | 3.10 | 21.7 | 6 | 1 | 1.99 | 1.99 | 1.99 | 5.96 | 75.1 | 10.53 | 1.7934 |
25 | 17 | 29.0 | 4.84 | 33.9 | 6 | 1 | 2.48 | 2.48 | 2.48 | 7.45 | 117.3 | 16.27 | 1.1478 |
40 | 17 | 46.5 | 7.75 | 54.2 | 6 | 1 | 3.14 | 3.14 | 3.14 | 9.42 | 187.7 | 25.79 | 0.7174 |
63 | 17 | 73.2 | 12.2 | 85.4 | 6 | 1 | 3.94 | 3.94 | 3.94 | 11.8 | 295.6 | 39.41 | 0.4555 |
100 | 6 | 116 | 6.46 | 123 | 18 | 1 | 2.87 | 2.87 | 2.87 | 14.3 | 369.9 | 46.86 | 0.2880 |
125 | 6 | 145 | 8.07 | 153 | 18 | 1 | 3.21 | 3.21 | 3.21 | 16.0 | 462.3 | 58.34 | 0.2304 |
125 | 16 | 145 | 23.7 | 169 | 26 | 7 | 2.67 | 2.07 | 6.22 | 16.9 | 585.4 | 81.50 | 0.2310 |
160 | 6 | 186 | 10.3 | 196 | 18 | 1 | 3.63 | 3.63 | 3.63 | 18.1 | 591.8 | 72.40 | 0.1800 |
160 | 16 | 186 | 30.3 | 216 | 26 | 7 | 3.02 | 2.35 | 7.04 | 19.1 | 749.4 | 103.11 | 0.1805 |
200 | 6 | 232 | 12.9 | 245 | 18 | 1 | 4.05 | 4.05 | 4.05 | 20.3 | 739.8 | 90.50 | 0.1440 |
200 | 16 | 232 | 37.8 | 270 | 26 | 7 | 3.37 | 2.62 | 7.87 | 21.4 | 936.7 | 128.89 | 0.1444 |
250 | 10 | 290 | 28.5 | 319 | 22 | 7 | 4.10 | 2.28 | 6.83 | 23.2 | 1023.2 | 131.72 | 0.1154 |
250 | 16 | 290 | 47.3 | 338 | 26 | 7 | 3.77 | 2.93 | 8.80 | 23.9 | 1170.9 | 158.21 | 0.1155 |
315 | 7 | 366 | 25.3 | 391 | 45 | 7 | 3.22 | 2.15 | 6.44 | 25.7 | 1207.9 | 155.64 | 0.0917 |
315 | 16 | 366 | 59.6 | 426 | 26 | 7 | 4.23 | 3.29 | 9.88 | 26.8 | 1475.3 | 197.55 | 0.0917 |
400 | 7 | 465 | 32.1 | 497 | 45 | 7 | 3.63 | 2.42 | 7.25 | 29.0 | 1533.9 | 191.71 | 0.0722 |
400 | 13 | 465 | 60.2 | 525 | 54 | 7 | 3.31 | 3.31 | 9.93 | 29.8 | 1754.9 | 234.19 | 0.0723 |
450 | 7 | 523 | 36.1 | 559 | 45 | 7 | 3.85 | 2.56 | 7.69 | 30.8 | 1725.6 | 215.67 | 0.0642 |
450 | 13 | 523 | 67.8 | 591 | 54 | 7 | 3.51 | 3.51 | 10.5 | 31.6 | 1974.2 | 255.52 | 0.0643 |
500 | 7 | 581 | 40.2 | 621 | 45 | 7 | 4.05 | 2.70 | 8.11 | 32.4 | 1917.3 | 239.63 | 0.0578 |
500 | 13 | 581 | 75.3 | 656 | 54 | 7 | 3.70 | 3.70 | 11.1 | 33.3 | 2193.6 | 283.91 | 0.0578 |
560 | 7 | 651 | 45.0 | 696 | 45 | 7 | 4.29 | 2.86 | 8.58 | 34.3 | 2147.4 | 268.39 | 0.0516 |
560 | 13 | 651 | 82.4 | 733 | 54 | 19 | 3.92 | 2.35 | 11.8 | 35.3 | 2444.0 | 321.17 | 0.0516 |
630 | 4 | 732 | 31.6 | 764 | 72 | 7 | 3.60 | 2.40 | 7.20 | 36.0 | 2269.4 | 275.18 | 0.0459 |
630 | 13 | 732 | 92.7 | 825 | 54 | 19 | 4.15 | 2.49 | 12.5 | 37.4 | 2749.5 | 361.32 | 0.0459 |
710 | 4 | 825 | 35.6 | 861 | 72 | 7 | 3.82 | 2.55 | 7.64 | 38.2 | 2557.6 | 310.12 | 0.0407 |
710 | 13 | 825 | 104 | 929 | 54 | 19 | 4.41 | 2.65 | 13.2 | 39.7 | 3098.6 | 407.20 | 0.0407 |
800 | 4 | 930 | 40.2 | 970 | 72 | 7 | 4.05 | 2.70 | 8.11 | 40.5 | 2881.8 | 349.43 | 0.0361 |
800 | 8 | 930 | 77.5 | 1007 | 84 | 7 | 3.75 | 3.75 | 11.3 | 41.3 | 3175.1 | 396.60 | 0.0362 |
900 | 4 | 1046 | 45.2 | 1091 | 72 | 7 | 4.30 | 2.87 | 8.60 | 43.0 | 3242.0 | 393.11 | 0.0321 |
900 | 8 | 1046 | 87.1 | 1133 | 84 | 7 | 3.98 | 3.98 | 11.9 | 43.8 | 3572.0 | 446.17 | 0.0322 |
1000 | 8 | 1162 | 94.6 | 1257 | 84 | 19 | 4.20 | 2.52 | 12.6 | 46.2 | 3954.1 | 499.40 | 0.0289 |
1120 | 8 | 1301 | 106 | 1407 | 84 | 19 | 4.44 | 2.66 | 13.3 | 48.9 | 4428.6 | 559.33 | 0.0258 |
Contact ways:
Tel: +86-15237106701
Website: htcable.cn
- Next: XLPE Insulated PVC Sheathed Flame Retardant Power Cable
- Previous: Copper Core PVC Insulated Power Cable for Hot Sale
Contact us