Mv-90, power Cable, 8 Kv, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)
Produktdetails
Basis Info
Zusätzliche Informationen.
Produktbeschreibung
MV-90, power Cable, 8 KV, 1/C, Cu/XLPE/CWS/PVC (ICEA S-93-639/NEMA WC74/UL 1072)
Feature
UL Listed as MV-90. Rated as Sunlight Resistance. Oil Resistance I jacket. True Triple extruding system and
closed handling raw material system, to eliminate any contact with ambient, until extruding process ends.
Application
Primary power and distribution circuits in industrial and commercial installation, power circuits into generating plants where LINE to ground faults current AR within shield capabilities. May fuel element used in wet or dry
locations, in valley LED in raceways, and open air duct, aerially or directly buried as permitted by NEC.
Standard
UL 1072: Medium VOL days power Cables.
ICEA S-93-639/NEMA WC74: 5 kV – 46 kV Shielded power Cables.
ICEA S-97-682: Standard for utility Shielded power Cables Rated 5 kV – 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded power Cables Rated 5 kV – 46 kV.
Specifications
Maximum operating VOL-meets: 5 kV to of 35 kV 100% and 133% IL
Maximum conductor operation of temperatures: Wet and dry locations: Normally: 90 °C, Emergency: 130 °C, Short Circuit: 250 °C
Engineering information
1. Conductor: Softly annealed uncoated copilot by compacted Class B by ASTM B496 or hard drawn Aluminum-1350 compacted Class B by ASTM B400. On request, beach falling LED or compressed beach. Sizes: 8 AWG (6 AWG Aluminum) UP to of 1000 kcmil.
2. Conductor Shield: Semi conducting CROSS linked polyethylenes (XLPE).
3. Insulation: Thermoset crosslinked polyethylenes (XLPE). On request, TR-XLPE.
4. Insulation Shield: Semi conducting CROSS linked polyethylenes (XLPE).
5. Metallic Shield: Solvently softly annealed uncoated copilot by wires by ASTM B3, helically applied and uniformly spaced.
6. Binder Tape: A suitable tape, as required.
7. Jacket: Black sunlight resistance and Fleming retardant polyvinyl of chlorides (PVC) compound.
100% Insulation level (115 mil) | 133% Insulation level (140 mil) | |||||||||||
Size | NUMBER OF of beach | Conductor nominal | Dia. meter of Over Insulation | Jacket Thickness | Approximate Outside dia. meter | Approximate Net Weight | Dia. meter of Over Insulation | Jacket Thickness | Approximate Outside dia. meter | Approximate Net Weight | ||
Copilot by | Aluminum | Copilot by | Aluminum | |||||||||
AWG OF kcmil | in | in | mil | in | lb/kft | in | mil | in | lb/kft | |||
6 | 7 | 0.17 | 0.43 | 60 | 0.68 | 257 | 200 | 0.48 | 60 | 0.73 | 280 | 224 |
4 | 7 | 0.21 | 0.48 | 60 | 0.73 | 321 | 231 | 0.53 | 60 | 0.78 | 345 | 256 |
2 | 7 | 0.27 | 0.53 | 60 | 0.78 | 422 | 279 | 0.58 | 80 | 0.87 | 482 | 339 |
1 | 19 | 0.30 | 0.56 | 60 | 0.81 | 485 | 305 | 0.61 | 80 | 0.90 | 548 | 368 |
1/0 | 19 | 0.34 | 0.6 | 80 | 0.89 | 601 | 374 | 0.65 | 80 | 0.94 | 631 | 405 |
2/0 | 19 | 0.38 | 0.64 | 80 | 0.93 | 703 | 416 | 0.69 | 80 | 0.98 | 734 | 448 |
3/0 | 19 | 0.42 | 0.69 | 80 | 0.98 | 829 | 469 | 0.74 | 80 | 1.03 | 863 | 502 |
4/0 | 19 | 0.48 | 0.74 | 80 | 1.03 | 986 | 532 | 0.79 | 80 | 1.08 | 1021 | 566 |
250 | 37 | 0.52 | 0.8 | 80 | 1.08 | 1136 | 598 | 0.85 | 80 | 1.13 | 1172 | 635 |
300 | 37 | 0.57 | 0.85 | 80 | 1.13 | 1310 | 666 | 0.90 | 80 | 1.18 | 1349 | 704 |
350 | 37 | 0.62 | 0.89 | 80 | 1.18 | 1485 | 732 | 0.94 | 80 | 1.23 | 1524 | 771 |
400 | 37 | 0.66 | 0.93 | 80 | 1.22 | 1657 | 797 | 0.98 | 80 | 1.27 | 1698 | 838 |
500 | 37 | 0.74 | 1.01 | 80 | 1.32 | 2021 | 946 | 1.06 | 80 | 1.37 | 2066 | 990 |
600 | 61 | 0.81 | 1.10 | 80 | 1.41 | 2376 | 1085 | 1.15 | 80 | 1.46 | 2423 | 1132 |
750 | 61 | 0.91 | 1.19 | 80 | 1.5 | 2880 | 1267 | 1.24 | 80 | 1.55 | 2930 | 1317 |
1000 | 61 | 1.06 | 1.35 | 80 | 1.66 | 3718 | 1568 | 1.40 | 110 | 1.77 | 3876 | 1726 |
- Next: Mv-90, Power Cable, 5 Kv, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)
- Previous: Aacsr, Aluminium Alloy Conductors Steel Reinforced (UNE 21.018)
Contact us
Ähnlich oder verwandt
-
Mv-90, Energien-Kabel, 35 KV, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)
-
Mv-90, Energien-Kabel, 35 KV, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)
-
Mv-90, Power Cable, 25 KV, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)
-
Mv-90, Power Cable, 5 KV, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)
-
Mv-90, Power Cable, 15 KV, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)