Primary Ud Cable, 35 Kv, Al/Epr/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)

 Primary Ud Cable, 35 Kv, Al/Epr/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)

Produktdetails

Basis Info

Modell Nr.:Primary UD Cable
Anwendung: U-Bahn
Spannung: Nieder-und Mittelspannung Kabel
Strom: DC-Kabel
Material Form: Runddraht
Bescheinigung: ISO , CCC

Zusätzliche Informationen.

Warenzeichen:DingAn or OEM
Verpackung:Heated Steel-Wooden Drum/Steel Drum
Standard:SGS
Herkunft:Jiangsu Yixing, China
HS-Code:8544601200
Produktionskapazität:12000 Km/Year

Produktbeschreibung

Primary UD Cable, 35 KV, Al/EPR/Neutral/LLDPE (AEIC CS 8/ICEA S-94-649)
Applications:
Predominantly used for primary underground distribution; Suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 15, 000 volts or less and at conductor temperatures not to exceed 90° C for normal operation.
Specifications:
Primary UD Cable meets or exceeds the following ASTM specifications:
B-3 Soft Annealed Copper Wire.
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft.
B-230 Aluminum, 1350-H19 Wire for Electrical Purposes.
B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded.
B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes.
Primary UD Cable is manufactured to the latest edition of the following specifications, and in case of specification conflicts, in the order listed:
ANSI/ICEA S-94-649
AEIC CS-8
RUS U-1
Construction:
The phase conductor is concentrically stranded, compressed soft copper or 1350-H16/26 aluminum alloy. The cable is composed of the conductor with moisture block in the strands, covered by a semi-conducting cross-linked polyethylene strand shield, an ethylene propylene rubber primary insulation, and a semi-conducting cross-linked polyethylene insulation shield. Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires and an insulating polyethylene jacket is applied over the insulation shield. The cable is identified by surface print on the jacket and with the lightning bolt symbol for supply cables indented in the jacket. A semi-conducting polyethylene jacket is available upon request.
Maximum Conductor Normal Operation: – 90O C;
Emergency Overload: – 130O C
Temperatures: Short Circuit – 250 C
Application: Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations. Application:

Features: 1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core, eliminating unequal electrical stress.
2. Ethylene Propylene Rubber (EPR) insulation offers: Excellent heat, moisture and corona resistance; Electrical stability under stress; Low dielectric loss, chemical resistance.

1/3 Neutral Full Neutral
Size AWG or kcmil Number of Strands Nominal OD Over Insulation in Number of Wires Size AWG Jacket Thickness mil Approximate Outside Diameter in Approximate Net Weight lb/kft Size AWG or kcmil Number of Strands Nominal OD Over Insulation in Number of Wires Size AWG Jacket Thickness mil Approximate Outside Diameter in Approximate Net Weight lb/kft
Aluminum 100% Insulation Level (345 mil)
1/0 1 1.06 6 14 50 1.38 858 1/0 1 1.06 16 14 50 1.38 979
1/0 19 1.10 6 14 50 1.42 895 1/0 19 1.10 16 14 50 1.42 1015
2/0 19 1.14 7 14 50 1.47 971 2/0 19 1.14 20 14 50 1.47 1127
3/0 19 1.19 9 14 50 1.52 1070 2/0 19 1.14 13 12 50 1.50 1167
4/0 19 1.25 11 14 50 1.57 1184 3/0 19 1.19 25 14 50 1.52 1263
250 37 1.30 13 14 80 1.69 1358 3/0 19 1.19 16 12 50 1.55 1300
350 37 1.40 18 14 80 1.79 1604 4/0 19 1.25 32 14 50 1.57 1437
500 37 1.53 25 14 80 1.95 1989 4/0 19 1.25 20 12 50 1.61 1468
500 37 1.53 16 12 80 1.99 2036 4/0 19 1.25 13 10 80 1.71 1592
750 61 1.74 24 12 80 2.19 2628 250 37 1.30 25 12 80 1.73 1716
750 61 1.74 15 10 80 2.24 2684 250 37 1.30 16 10 80 1.77 1772
1000 61 1.89 31 12 80 2.34 3139 350 37 1.40 32 12 80 1.83 2038
1000 61 1.89 20 10 80 2.38 3217 350 37 1.40 20 10 80 1.87 2084
1000 61 1.89 16 9 80 2.41 3260 350 37 1.40 16 9 80 1.89 2119
500 37 1.53 29 10 80 2.03 2667
750 61 1.74 28 8 80 2.29 3661
1000 61 1.89 37 8 80 2.44 4483
Aluminum 133% Insulation Level (420 mil)
1/0 19 1.25 6 14 50 1.57 1076 1/0 19 1.25 16 14 50 1.57 1196
2/0 19 1.29 7 14 50 1.62 1157 2/0 19 1.29 20 14 80 1.68 1380
3/0 19 1.34 9 14 80 1.73 1331 2/0 19 1.29 13 12 80 1.71 1424
4/0 19 1.40 11 14 80 1.79 1454 3/0 19 1.34 25 14 80 1.73 1524
250 37 1.45 13 14 80 1.84 1571 3/0 19 1.34 16 12 80 1.76 1566
350 37 1.56 18 14 80 1.98 1876 4/0 19 1.40 32 14 80 1.79 1707
500 37 1.68 25 14 80 2.11 2235 4/0 19 1.40 20 12 80 1.82 1743
500 37 1.68 16 12 80 2.14 2285 4/0 19 1.40 13 10 80 1.86 1805
750 61 1.89 24 12 80 2.34 2902 250 37 1.45 25 12 80 1.88 1933
750 61 1.89 15 10 80 2.39 2963 250 37 1.45 16 10 80 1.92 1992
1000 61 2.04 16 9 80 2.56 3560 350 37 1.56 32 12 80 2.01 2314
350 37 1.56 20 10 80 2.05 2365
350 37 1.56 16 9 80 2.08 2403
500 37 1.68 29 10 80 2.18 2920