YKXS, Power Cable, 0.6/1 KV, AL/XLPE/PVC (IEC 60502-1)
Power cables with XLPE insulation
DESIGN
1 | Copper conductor, round solid (RE), round stranded (RM), resp. sector-shaped stranded (SM)
2 | Core insulation (XLPE)
3 | Inner covering (EPDM or plastic tape)
4 | Sheath (PVC black, UV-resistant)
Standard: DIN VDE 0276-604
Application
Power distribution cables in power stations, industrial installations and switchgears. For fi xed installation underground, in interior premises, cable ducts, in the open air, in the ground or concrete, in water – as permitted by the local building regulations – if no risk of any mechanical damage is to be expected.
Properties
Rated voltage: 0,6/1 kV
Test voltage: 4 kV
Max. conductor temperature: +90 °C
Max. short-circuit temperature: +250 °
Temperature range for handling: -35 up to +90 °C
Min. temperature for laying and manipulation: -5 °C
Min. storage temperature: -35 °C
Colour of insulation: HD 308 S2
Core identifi cation: HD 308 S2
Fire properties: flame retardant: EN 60332-1-2
Number of cores x nominal cross section | Max. conductor resistance | Current rating in the ground | Current rating in the air | Outer diameter | Total weight |
(mm²) | (Ω/km) | (A) | (A) | (mm) | (kg/km) |
E-XAYY | |||||
3 x 1.5 RE | 12.100 | 31 | 24 | 10.8 | 180 |
4 x 10 RE | 1.830 | 86 | 74 | 16.8 | 630 |
1 x 25 RM | 0.727 | 229 | 177 | 11.8 | 325 |
4 x 25 RM | 0.727 | 145 | 133 | 23.6 | 1380 |
5 x 25 RM | 0.727 | 145 | 133 | 26.3 | 1,650 |
1 x 35 RM | 0.524 | 275 | 217 | 13 | 430 |
4 x 35 SM | 0.524 | 174 | 162 | 23.7 | 1,530 |
5 x 35 RM | 0.524 | 174 | 162 | 29.6 | 2,190 |
1 x 50 RM | 0.387 | 326 | 265 | 14.4 | 580 |
4 x 50 SM | 0.387 | 206 | 197 | 27.1 | 2,180 |
5 x 50 SM | 0.387 | 206 | 197 | 30.7 | 2,560 |
1 x 70 RM | 0.268 | 400 | 336 | 16.2 | 785 |
4 x 70 SM | 0.268 | 254 | 250 | 31.0 | 2,950 |
5 x 70 SM | 0.268 | 254 | 250 | 35.0 | 3,560 |
1 x 95 RM | 0.193 | 480 | 415 | 17.9 | 1,030 |
4 x 95 SM | 0.193 | 305 | 308 | 35.3 | 3,830 |
5 x 95 SM | 0.193 | 305 | 308 | 39.8 | 4,850 |
1 x 120 RM | 0.153 | 548 | 485 | 19.6 | 1,290 |
4 x 120 SM | 0.153 | 348 | 359 | 39.1 | 4,810 |
5 x 120 SM | 0.153 | 348 | 359 | 43.5 | 6,080 |
1 x 150 RM | 0.124 | 616 | 557 | 21.2 | 1,620 |
4 x 150 SM | 0.124 | 392 | 412 | 43.2 | 5,880 |
5 x 150 SM | 0.124 | 392 | 412 | 48.2 | 7,470 |
1 x 185 RM | 0.099 | 698 | 646 | 23.6 | 1,980 |
4 x 185 SM | 0.099 | 444 | 475 | 48.7 | 7,400 |
5 x 185 SM | 0.099 | 444 | 475 | 53.0 | 9,230 |
1 x 240 RM | 0.075 | 815 | 774 | 26.6 | 2,440 |
4 x 240 SM | 0.075 | 517 | 564 | 54.3 | 9,620 |
5 x 240 SM | 0.075 | 517 | 564 | 59.5 | 12,050 |
1 x 300 RM | 0.06 | 927 | 901 | 29.1 | 3,100 |
1 x 400 RM | 0.047 | 1064 | 1060 | 32.7 | 3,940 |
1 x 500 RM | 0.037 | 1227 | 1252 | 36.3 | 4,970 |